[FACA-200-ISE] Fully Automatic Chemistry Analyzer w/ 320 Test/Hr, Electrolyte Tester

[FACA-200-ISE] Fully Automatic Chemistry Analyzer w/ 320 Test/Hr, Electrolyte Tester

This automatic biochemistry analyzer comes with varying testing capabilities that conducts 320 tests per hour with true random access and 10 filters: 340nm, 405nm, 450nm, 492nm, 505nm, 546nm, 578nm, 620nm, 670nm, 700nm Additional filters can be added.

Print Product Page

Description

Features

Each set of FACA will come with one video to train in the installation, operation, and maintenance of the biochemistry analyzer.

System Functions

Type: Fully Automated, Random Access Biochemistry Analyzer.
Throughput: 200 tests, up to 320 tests/hr with ISE (optional).
Test Mode:  End point, Kinetics, Fixed Time, lmmunoturbidimetry, Monochromatic, Bi-chromatic and Multi-Standard Analysis, Linearity and Nonlinearity Calibration, Single and Dual Reagents  can be used.
Test Setting: Programmable for single-parameter, multi-parameter, combined parameter, batch test.
Parameter Setting: Completely open for editing test 3ertyuio

1 parameters and calculation parameters.

Sample System
Sample Tray:  44 sample positions for primary tubes, test tubes and various sample cups, Whole sample tray is removable and replaceable. Any position can be aligned as the emergency test position.
Sample Volume: 3 µL ““ 30 µL, programmed by 0.1 µL step.
Sample Handling: Dilute and  retest automatically when the sample’ s concentration is beyond limitation.
Sample Probe: Liquid level detection and collision protection.
Probe cleaning:  Automatic washing for both inside and outside, carry over <0.1%.
Syringe: High performance syringe, durable  and  maintenance free.
Optional item: Bar code reader.

Reagent System
Reagent Tray: 44 positions for Single and Dual reagents, reagent positions can be aligned freely.
Refrigeration:  Refrigerated reagent compartment, 24 hours non-stop cooling with Peltier element to maintain temperature 4-15 „ƒ.
Reagent Bottle Volume: 40ml and 15ml, Slope bottom design.
Reagent volume:  150 µL – 300 µL, prograrnmed by 0.1µ1 step.
Reagent Probe: Automatically detecting the liquid level; collision protection.
Reagent pre-heating function, inventory checking.
Real time monitoring of reagent residual volume and auto alarm.
Probe Cleaning:  Washing  for  both  inside and outside, carry over <0. 1%.

Reaction System
Reaction Tray: 44 reaction cuvettes with 6mm optical path, good UV penetrability, low consumable, low cost.
Reaction Technology: Back ““ Dividing ““ Light ““ Technology.
Reaction Volume: 250 µL – 300 µL.
Temperature: 37„ƒ, with 0.1„ƒ fluctuation.
Mixing System: Independent mixer.
Cleaning: Supports automatic cleaning of cuvettes and allows for complete drainage to reduce carry over.
Water consumption: 3L/hour.
Liquid Detection: Detergent, distilled water, waste liquid automatic detection and alarm.

Optical  System
Light Source:  Halogen lamp 6V/ 10W, life span > 3000 hours.
Wavelength:  340nm, 405nm, 450nm, 492nm, 505ml, 546nm, 578nm, 620nm, 670nm, 700nm
Wavelength  Accuracy:   2nm.
Detector:  Photoelectron Diode Array.
Absorbance Range: 0.000 Abs -3.000 Abs.

Calibration and Quality Control
Calibration Mode:  Linear (one-point, two-point  and rnulti-point ), Logit-Log4P, Logit-Log5P, Spline, Exponential, Polynomial, Parabola.
QC Rules:  Westgard Multi-rule.
QC Mode:  Intra-day  and inter-day QC.

Operating System
Computer:  Windows 2000 System or above.
Data Management:  Large capacity for results and reaction curves to be displayed, saved and printed.
Report: Edit and print complete reports, format editable, supports network printing.
Port:  RS-232.

Filters:

FACA200 will have 10 filters 340,405,450,492,505,546,578,620,670,700nm

Working  Conditions
Power: 220V ±22V, 50/60Hz ± 1Hz
Power Consumption: <400VA
Environmental    Temperature: 15„ƒ – 30„ƒ
Humidity:  <85%
Dimension: 85x75x75 cm (LxWxH)
Weight: 145 Kgs

Accessories

Item Specification
Quantity
Reagent bottle 1 40ml 50Pcs
Reagent bottle 2 with holder 15ml 15Pcs
Reaction cuvette 80pcs
Serum Cup 1000pcs
Tube 1 set
Fuse(4A/8A) 4 sets
Lamp(13.8V/50W) 1Pc
Power cable 2Pcs
Com Cable 1Pc
User manual Operation software
Tool 1 set
Sensor 1Pc
Detect Probe, 2Pcs
Sample Probe 1Pc
Ground Cable 1Pc

(all of these accessories are included with the FACA-200)

OPTIONAL TESTING REAGENT PACKAGE FOR 10,000 TESTS WITH 20 PARAMETERS FOR FULLY AUTOMATIC AND SEMI-AUTOMATIC BIOCHEMISTRY ANALYZERS
Liver Function
Rg1 Alanine Aminotransferase ALT/GPT
Aspartate Aminotransferase AST/GOT
y-Glutamyltransferase y-GT/GGT
Alkaline Phosphatase ALP/AKP
Direct Bilirubin* DBILI
Total Protein* TP
Albumin* ALB
Renal function
Urea* UREA
Creatinine* CREA
Uric Acid* UA
Blood Fat
Cholesterol* CHOL
Triglycerides* TG
High Density Lipoprotein Cholesterol HDL-C
Cardiac Muscle
Creatine Kinase CK
Microelements
Calcium* Ca
Inorganic Phosphorus* p
Magnesium* Mg
Iron* Fe
Saccharides
Glucose* GLU
Glucose* GLU

OPTIONAL ACCESSORIES FOR FACA
FACA ““ Lamp LAMP
FACA- Stirring -Probe Stirring Probe
FACA- Sample -Probe Sample Probe
Reagent Probe Reagent Probe
FACA Reagent -Cuvettes Reagent -Cuvettes
FACA Sample Cuvettes Serum Cuvettes Sample
FACA Reagent -Bottles Reagent -Bottles
FACA ““ Fuse
Go to Top