This automatic biochemistry analyzer comes with varying testing capabilities that conducts 200 tests per hour with true random access and 10 filters: 340nm, 405nm, 450nm, 492nm, 505nm, 546nm, 578nm, 620nm, 670nm, 700nm Additional filters can be added.
Print Product Page[FACA-200] Fully Automatic Chemistry Analyzer w/ 200 Tests/Hr
Description
Features
Each set of FACA will come with one video to train in the installation, operation, and maintenance of the biochemistry analyzer.
System Functions
Type: Fully Automated, Random Access Biochemistry Analyzer.
Throughput: 200 tests, up to 320 tests/hr with ISE (optional).
Test Mode: End point, Kinetics, Fixed Time, lmmunoturbidimetry, Monochromatic, Bi-chromatic and Multi-Standard Analysis, Linearity and Nonlinearity Calibration, Single and Dual Reagents can be used.
Test Setting: Programmable for single-parameter, multi-parameter, combined parameter, batch test.
Parameter Setting: Completely open for editing test 3ertyuio
1 parameters and calculation parameters.
Sample System
Sample Tray: 44 sample positions for primary tubes, test tubes and various sample cups, Whole sample tray is removable and replaceable. Any position can be aligned as the emergency test position.
Sample Volume: 3 µL ““ 30 µL, programmed by 0.1 µL step.
Sample Handling: Dilute and retest automatically when the sample’ s concentration is beyond limitation.
Sample Probe: Liquid level detection and collision protection.
Probe cleaning: Automatic washing for both inside and outside, carry over <0.1%.
Syringe: High performance syringe, durable and maintenance free.
Optional item: Barcode reader.
Reagent System
Reagent Tray: 44 positions for Single and Dual reagents, reagent positions can be aligned freely.
Refrigeration: Refrigerated reagent compartment, 24 hours non-stop cooling with Peltier element to maintain temperature 4-15 „ƒ.
Reagent Bottle Volume: 40ml and 15ml, Slope bottom design.
Reagent volume: 150 µL – 300 µL, prograrnmed by 0.1µ1 step.
Reagent Probe: Automatically detecting the liquid level; collision protection.
Reagent pre-heating function, inventory checking.
Real time monitoring of reagent residual volume and auto alarm.
Probe Cleaning: Washing for both inside and outside, carry over <0. 1%.
Reaction System
Reaction Tray: 44 reaction cuvettes with 6mm optical path, good UV penetrability, low consumable, low cost.
Reaction Technology: Back ““ Dividing ““ Light ““ Technology.
Reaction Volume: 250 µL – 300 µL.
Temperature: 37„ƒ, with 0.1„ƒ fluctuation.
Mixing System: Independent mixer.
Cleaning: Supports automatic cleaning of cuvettes and allows for complete drainage to reduce carry over.
Water consumption: 3L/hour.
Liquid Detection: Detergent, distilled water, waste liquid automatic detection and alarm.
Optical System
Light Source: Halogen lamp 6V/ 10W, life span > 3000 hours.
Wavelength: 340nm, 405nm, 450nm, 492nm, 505ml, 546nm, 578nm, 620nm, 670nm, 700nm
Wavelength Accuracy: 2nm.
Detector: Photoelectron Diode Array.
Absorbance Range: 0.000 Abs -3.000 Abs.
Calibration and Quality Control
Calibration Mode: Linear (one-point, two-point and rnulti-point ), Logit-Log4P, Logit-Log5P, Spline, Exponential, Polynomial, Parabola.
QC Rules: Westgard Multi-rule.
QC Mode: Intra-day and inter-day QC.
Operating System
Computer: Windows 2000 System or above.
Data Management: Large capacity for results and reaction curves to be displayed, saved and printed.
Report: Edit and print complete reports, format editable, supports network printing.
Port: RS-232.
Filters:
FACA200 will have 10 filters 340,405,450,492,505,546,578,620,670,700nm
Working Conditions
Power: 220V ±22V, 50/60Hz ± 1Hz
Power Consumption: <400VA
Environmental Temperature: 15„ƒ – 30„ƒ
Humidity: <85%
Dimension: 760 (L) x 560 (W) X 530 (H) mm
Weight: 145 Kgs
OPTIONAL TESTING REAGENT PACKAGE FOR 10,000 TESTS WITH 20 PARAMETERS FOR FULLY AUTOMATIC AND SEMI-AUTOMATIC BIOCHEMISTRY ANALYZERS | ||
Liver Function | ||
Rg1 | Alanine Aminotransferase | ALT/GPT |
Aspartate Aminotransferase | AST/GOT | |
y-Glutamyltransferase | y-GT/GGT | |
Alkaline Phosphatase | ALP/AKP | |
Direct Bilirubin* | DBILI | |
Total Protein* | TP | |
Albumin* | ALB | |
Renal function | ||
Urea* | UREA | |
Creatinine* | CREA | |
Uric Acid* | UA | |
Blood Fat | ||
Cholesterol* | CHOL | |
Triglycerides* | TG | |
High Density Lipoprotein Cholesterol | HDL-C | |
Cardiac Muscle | ||
Creatine Kinase | CK | |
Microelements | ||
Calcium* | Ca | |
Inorganic Phosphorus* | p | |
Magnesium* | Mg | |
Iron* | Fe | |
Saccharides | ||
Glucose* | GLU | |
Glucose* | GLU | |
OPTIONAL ACCESSORIES FOR FACA | ||
FACA ““ Lamp | LAMP | |
FACA- Stirring -Probe | Stirring Probe | |
FACA- Sample -Probe | Sample Probe | |
Reagent Probe | Reagent Probe | |
FACA Reagent -Cuvettes | Reagent -Cuvettes | |
FACA Sample Cuvettes | Serum Cuvettes Sample | |
FACA Reagent -Bottles | Reagent -Bottles | |
FACA ““ Fuse |