[AAS-3900] Atomic Absorption Spectrophotometer Fully-Automatic Combined Flame & Graphite Furnace System

[AAS-3900] Atomic Absorption Spectrophotometer Fully-Automatic Combined Flame & Graphite Furnace System

Atomic Absorption Spectrophotometer AAS-3900 is a high performance automated instrument designed to meet the requirements of the modern laboratory. Due to its versatility and performance it can be used for a wide range of applications including: Agricultural, Clinical, Environmental, Food, Metal, Mining, Geological, Petrochemical, and Pharmaceutical.

Print Product Page

Description

The instrument is equipped with a Graphite Furnace Atomizer only. The graphite head is fixed into the optical path to maximize performance and eliminate drift. The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system. Pyrolytically coated platform tubes are supplied as standard to improve the performance and eliminate many analytical problems associated with this technique.

The Fully Automatic Fast Sequential Multi-Element Analysis Graphite Furnace Atomic Absorption Spectrometer system is equipped with an EIGHT Hollow cathode lamp motorized turret Atomic Absorption Spectrophotometer. The graphite furnace heating cycle, all electronic functions, analytical data and gases are fully controlled via the AAWin3 Software for maximum safety and optimum performance.

FEATURES AND FUNCTIONS:

  • TPC System is used to control the instrument. Pre-installed AA-Win Pro software, user manuals, cook book and Windows 7 professional operating system.
  • AA-Win Pro software provides full control of the instrument and autosampler with easy method change for each technique.
  • Automatic 8 Hollow Cathode lamp turret controlled and optimized by the AA-Win Pro software. Operating lamp current and warm-up lamp current can be individually controlled to eliminate drift commonly associated with lamp warming.
  • D2 lamp background correction system fitted as standard to all configurations. High energy D2 lamp and adjustable beam splitter mirror are optimized by the AA-Win pro software.
  • Self background correction system fitted as standard to all configurations. The high performance background system uses the same hollow cathode lamp as installed for the analysis. Minimum extra components are required and optical alignment is very simple. Self Reversal can be used for any element at any wavelength, making it extremely versatile.
  • High precision minimal optics ensures maximum light throughput to the computer controlled Czerny-Turner monochromator.
  • A universal autosampler is available as an optional accessory which is conveniently mounted on the front of the AAS-3900 instrument.
  • The temperature of the transversely heated graphite tube is accurately controlled by means of a precision feedback system and has been designed to reduce analytical problems normally associated with this type of technique.
  • Pyrolytically coated graphite tubes are used as standard and are manufactured to improve performance, as well as to increase the analytical life.
  • Platform graphite tubes are supplied as standard and will accept volumes up to 20ul. Non-platform graphite tubes are also available as an optional extra.
  • Up to 10 heat stages are available for the programming of the graphite atomizer. These can be set and stored within the AA-WinPro software.
  • The graphite tube is held in position by means of a gas piston. Replacement of the graphite tube is performed by a simple command in the AA-Win Software.
  • The graphite tube is efficiently cooled by an additional water circulation system (supplied separately).

Air/Acetylene

  • The Air/Acetylene flame uses a 100mm single slot burner for the standard configuration.
  • The high sensitivity (Cu 2ppm >0.280abs) is due to the efficiency of the fixed position glass nebulizer fitted as standard. An acid resistant replacement is available as an option.
  • The flame can be easily set from blue lean flame through stoichiometric to fuel rich by means of computer control.

N20/Acetylene

  • The N20/Acetylene flame uses a 50mm single slot burner and is available as an optional extra.
  • This flame configuration is used to measure elements less prone to ionization such as: Aluminium, Tin, Titanium, Calcium, Vanadium and Molybdenum.
    Switching from Air/Acetylene to N20/Acetylene to Flame Off is fully controlled by the AAWinPro software.

Air/Propane (LPG)

  • This flame uses a 3 slot burner and with the Iow pressure requirement, it is also much safer to operate.
    Due to the low temperature of the flame, it is ideal for analyzing alkali metals such as: Potassium, Sodium and Lithium, especially when used in the emission mode.
    Some remote areas of the world have difficulty obtaining Acetylene gas of a high enough purity to operate the flame correctly, LPG can give a real alternative and offer comparable results for most elements throughout the wavelength range.

FLAME ATOMIZER FEATURES

The flame atomizer offers three flame options: Air/acetylene is the standard configuration, with the N20/acetylene and Air/LPG as options.

SAFETY FEATURES

  • Pressure monitoring for all gases
  • Burner Identification
  • Flame sensor
  • Drain Trap Level Sensor
  • Gas Leak Detector
  • Over Pressure in Premix
  • Safety Cut off Switch

SAFETY FEATURES

  • Argon Gas Pressure Sensor
  • Water Flow Sensor
  • Over Temperature Sensor
  • Broken Graphite Tube Protection

GRAPHITE ATOMIZER FEATURES

  • The integrated Graphite Furnace Atomizer is available in two instrument configurations:
  • In the AAS-3900 instrument, the graphite furnace head is fixed into the light path, so alignment with the optical path is simple and accurate.
  • In the AAS-4100 instrument the graphite furnace head is fixed behind the flame atomizer assembly and is motorized into position by a simple operation in the AA-WinPro software. The positions for the flame and graphite are saved, making it easy to swap between modes for different analysis.

Accessories

Description

Quantity

AAS-3900 Main unit 1
AAS-3900 Graphite furnace power supply 1
HCL Holder(1,2,3,4,5,6,7,8) 8
Control Cable (For Furnace Power Unit) 1
Power Cord (For Main unit ,US Standard) 1
RS-232 Cable (For Main unit ) 1
USB Communication Cable 1
Path Aiming Block 1
Water Tubing Sleeves 1
Graphite Tubes with Platform 10
Fuses for power (3.15A) 4
Double Offset Ring Spanner 10×13 1
Reflection mirror 1
Tweezers 1
Pipette (5-50uL) 1
Pipette Tip 100
PVC Hose for Argon (Ф8×Ф15, black, 10m) 1
PA Tube for Argon (Ф6×1, black, 0.5m) 1
PA Tube for Water (Ф8×1, white, 10m) 1
Filter 1
Hose clamps 2
Atomization compartment Door 1
Sample Salver 1
Cooling water flow rate control valve 1
USB flash memory 1

Accessories that are more economical
to purchase locally from local producers

Description

Quantity

Notes

Computer

1


Argon gas

1

Purity higher than 99.99%


Air Regulator

2

Circulating Cooling System

1

Water Purification System

1

Oil Free Air Compressor

1

Acetylene Gas

1

Purity higher than 99.99%

Air Switch or Equivalent Switch

1

Vent Fan

1

Necessary Optional Accessories that can be used with AAS-3900

Part Number

Image

Name & Description

Auto G-4000

Graphite Furnace Auto Sampler

  • Measures 76 samples at one time automatically

H-4000

Hydride Generator

  • Universal design

  • Full reaction cycle from press of start button

  • Supplied with temperature controlled heated absorption cell

  • Cell is easily installed with burner attachment

  • Can be used for Mercury cold vapour analysis

  • Sensitivity for most elements <lng/mi

  • Only 2.0mi – 2.5ml per sample required

  • RSD < 3%

  • Quick analysis < 30 seconds per measurement

CM-4000

Air Compressor

  • Rated discharge presure: 0.3Mpa

  • Output Rate: 0.3-0.9m3/h (adjustable)

  • Noise: smaller than 55dB

  • Power Supply: AC220V 50Hz

  • Dimension:400x300x620(mm)

  • Ambient Condition: ambient temperature less than 35°C Relative humidity less than 80%

HC-01

Hollow Cathode Lamp

  • Sharp line source

  • About 5000 milliampere-hours

Second Optional Accessories (Depends on demand)

Part Number

Image

Name & Description

Auto F-4000

Flame Auto Sampler

  • Analysis of 50 or more sample and calibration standards

CW-4000

Water Circulator

  • Cooling capacity 2000W

  • Temperature range 0-50°C

  • Temperature accuracy 1°C

  • Maximum input power 1000W

  • Fuse 10A

  • Power 220V 50 Hz

  • Work Pressure 0~0.6 MPa

  • Rated flow rate 3.5L/min

  • Rated lift 10M

  • Tank capacity 32L

  • Noisiness <65

  • Dimension (LxWxH) 600x400x900

  • Weight 50Kg

Additional information

Weight 85 kg

Optional Accessories

Go to Top